Sprinkler Winterization in Utah
Blowouts at the pressure the pipe is rated for, done before the first hard freeze. Utah County and the Wasatch Front.
- Utah contractor license 10726295-5501
- Over 20 years in business
- Parade of Homes People’s Choice
- 4.8 from 45 Google reviews
- Free estimates, no obligation
- Based in Lindon, Utah
Sprinkler winterization in Utah is a one week job for the whole county, and almost everyone leaves it until the week after they should have.
Pleasant Grove turns its pressurized irrigation mains off on 9 October. American Fork runs its season from 15 April to 15 October. Lehi and Highland want connections off by 15 October, Saratoga Springs drains the week of the fifteenth, Lindon goes mid month. Provo’s average first fall frost, on the 1991 to 2020 NOAA normals from the BYU station, is 16 October.
Line those dates up and the gap between the city turning the water off and the ground starting to freeze is about a week. The water already sitting in your laterals does not care that the supply has been shut. That week is the whole job.
A blowout, and the one number that matters
A blowout is compressed air pushed through each zone until the line runs dry. The part people get wrong is the pressure, and it is not a matter of opinion. Hunter, who makes a large share of the heads and valves in Utah County yards, publish a ceiling of 50 PSI for polyethylene pipe and 80 PSI for PVC. Most residential laterals here are poly, so fifty is the working limit.
Going above it does not clear water any faster. It damages seals, strips gears in rotor heads and blows fittings apart, and the failures show up in April rather than in October, which is why the connection between the two is so rarely made.
Volume does the work, not pressure. Hunter’s own rule is to take the gallons per minute of your largest zone and divide by 7.5. That is the cubic feet per minute you need at the connection point. A pancake compressor from the hardware store makes plenty of pressure and almost no volume, which is why a DIY blowout pushes a little water, stalls, and leaves the rest of it in the pipe.
Two more rules from the same source, both of which get broken constantly. Never blow air through a backflow device or a pump. And stop as soon as a zone runs dry, because air moving through dry pipe builds friction heat and that is its own kind of damage.
Your city shutting the water off is not winterizing
This is the single most common misunderstanding we run into. The city closing the main stops new water arriving. It does nothing at all about the water already in your system, and that is the water that splits the fittings.
Two local details worth knowing, because both run against what people assume.
Pleasant Grove tells residents to leave their own valve open until Thanksgiving. Not closed. Open. The reasoning is that water from the street mains can be pushed back into a closed system, and the city warns plainly that closing your valve early can leave water trapped in your pipes. If you have been dutifully shutting yours the day the city shuts theirs, you have been doing the opposite of what your own city asks.
In American Fork you are no longer allowed to use the city shutoff. Because of the pressurized irrigation meter project, which started with new connections in 2019 and reached existing ones from 2022, residents are told not to use the city’s PI utility box or its shutoff valve at all. If there is no valve further down your own line, install one before the next watering season, because without one you have no way to isolate your system.
Orem and Provo are a different job entirely
Neither city runs a general pressurized irrigation system. Orem’s water plan says so directly, and Provo’s 2026 plan describes none. So there is no October shutoff date to work back from. Your sprinklers run on culinary water, the only valve that matters is yours, and the timing comes from the forecast rather than a city calendar.
It also means the bill works differently. On a metered culinary system every gallon you put through the sprinklers is billed at drinking water rates, so an unwinterized leak that weeps all winter is not just a repair, it is a bill. Worth knowing if you are weighing up water-wise landscaping, where the rebates run to $3.00 a square foot through Central Utah Water Conservancy District.
Pages for Orem, Provo and Lehi go into the local water rules in more detail.
The backflow preventer is what actually breaks
If one component is going to fail over winter, it is this one. It is brass, it sits above ground, it holds water, and it is therefore the first thing in the whole system to reach freezing. It is also the most expensive single part on a typical residential setup to replace.
Which is the real argument for having the job done properly. The cost of a winterization visit is set against the cost of one brass assembly, plus the labor to cut it out and fit a new one, plus the fact that it will be discovered in April when every irrigation company in the county is already booked three weeks out.
What happens on a winterization visit
- Close the supply and relieve the pressure. Your valve, not the city’s. In American Fork that is now a requirement rather than a preference. We open a test cock to take the standing pressure off before anything else happens.
- Connect air downstream of the backflow. Never through it. The backflow is drained on its own through the test cocks and left with the ball valves at roughly forty five degrees so any trace of water has somewhere to expand.
- Open a zone before the compressor runs. Air with nowhere to go is how fittings get blown off. There is always at least one valve open before the air is on.
- Work zone by zone, under the pipe rating. Fifty PSI on polyethylene, eighty on PVC. We work from the zone furthest from the connection back toward it, because the far end is where water hides.
- Stop the moment a zone runs dry. Dry pipe with air still moving through it builds friction heat, and that is its own kind of damage. When the head stops spitting mist, that zone is done.
- Drain and protect the backflow. Test cocks open, body drained, insulated cover on. This is the component that actually fails, so it gets the attention.
- Shut the controller down properly. Off or rain mode rather than unplugged, so the program and the clock survive the winter and spring startup is a five minute job.
- Write down what needs fixing. Every leak, stuck valve and broken head the blowout exposes, noted while the system is still under air and the evidence is in front of us.
What sprinkler winterization costs
Sprinkler winterization Utah County rates move with things we cannot see from the road, so we do not publish a flat number. Here is what actually changes it, so you can judge roughly where your system sits before you call.
- Zone count. The single biggest factor. A four zone yard and a fourteen zone yard are not the same visit.
- Whether there is a usable blowout point. Systems fitted with a proper connection take minutes. Systems without one have to be opened up somewhere, which takes longer and sometimes means fitting a point so next year is simple.
- Backflow type and location. A pressure vacuum breaker in an accessible spot is quick. A reduced pressure assembly buried behind shrubs is not.
- Drip zones. They blow out differently from spray zones and the filters and pressure reducers need handling separately.
- What the blowout finds. Running every zone under air is the best diagnostic of the year, and sometimes it turns up a problem that needs dealing with before spring.
Book before the end of September if you can. The entire county wants this done in the same ten days, and the people who call after the first frost warning are the people who get told the following week.
Where we winterize
We handle sprinkler winterization Utah County wide, plus the north end of the Wasatch Front. Each city page covers the local water rules, soil and what we have built there.
Spring startups, repairs and new installations are sprinkler repair and install work. Ongoing seasonal care sits under property care. For a new build with no system in the ground yet, see new construction landscaping.
Sprinkler winterization Utah FAQs
What customers say
4.8 stars from 45 reviews on Google. Three of them, dated, so you can see they are current.
“Stefan showed up and quickly winterized my system after checking the zones. He also checked for broken sprinkler heads. Grateful to quick, friendly service!”
“Winterized my sprinklers! Thanks!”
“Viking was great and took care of getting all of our sprinkers winterized for us!”
Recent work
Projects built by our own crews across Utah County and the Wasatch Front.
New projects go up here first.
When should sprinkler winterization happen in Utah County?
Before the first hard freeze, which in practice means the first half of October. Provo’s average first fall frost is 16 October on the 1991 to 2020 NOAA normals from the BYU station, and most Utah County cities shut their pressurized irrigation down around the same week. That leaves a narrow window, which is why October books out fast.
Is a blowout actually necessary, or can I just drain the system?
Manual and automatic drains only empty the pipe where they sit. Anything in a low spot, a riser, a lateral that runs uphill or a head body stays full. In a climate that freezes and thaws repeatedly from October to March, that trapped water is what splits fittings. A blowout is the only method that clears the whole run.
What air pressure should be used on a sprinkler blowout?
Hunter publishes a ceiling of 50 PSI for polyethylene pipe and 80 PSI for PVC. Most Utah County residential laterals are poly, so 50 is the working limit. Higher pressure does not clear water faster, it just damages seals, gears and fittings.
Why does a small air compressor never seem to do the job?
Because volume clears the line, not pressure. Hunter’s rule is to divide the gallons per minute of your largest zone by 7.5 to get the cubic feet per minute you need at the connection. A pancake compressor makes plenty of pressure and almost no volume, so it pushes a little water, stalls, and leaves the rest sitting in the pipe.
Can air be blown through the backflow preventer?
No. Hunter is explicit that air should never be blown through a backflow device or a pump. Air goes in downstream of it, and the backflow itself is drained separately through its test cocks.
My city shuts the secondary water off. Is my system winterized?
No. The city shutting the main off stops new water arriving. It does nothing about the water already sitting in your laterals, and that is the water that freezes.
Should I close my own irrigation valve as soon as the city shuts the water off?
In Pleasant Grove, no. The city tells residents to leave their valve open until Thanksgiving so water from the street mains cannot be pushed back into their system, and warns that closing it earlier can leave water trapped in the pipes. Check your own city, because this is one of the few places where the usual advice is backwards.
I am in American Fork. Can I use the city shutoff valve in the box?
Not any more. Because of the pressurized irrigation meter project, American Fork tells residents they must no longer use the city’s PI utility box or the city shutoff valve. If there is no valve further down your own line, install one before the next watering season.
I am in Orem or Provo. When does my secondary water get shut off?
It does not, because neither city runs a general pressurized irrigation system. Orem’s water plan states it and Provo’s 2026 plan describes none. Your sprinklers run on culinary water, so there is no city calendar to work to and the timing comes from the forecast instead.
What usually breaks first when a system is not winterized?
The backflow preventer. It is brass, it sits above ground, it holds water, and it is the first thing to reach freezing. It is also the most expensive single component on a residential system to replace, which is what makes a blowout cheap by comparison.
Do you fix problems you find during the blowout?
We note them. A blowout is the best diagnostic of the year because every zone runs under air and leaks, stuck valves and broken heads show themselves. We write down what needs doing so it can be handled at startup rather than discovered in April. Repairs themselves are sprinkler repair and install work.
Do you winterize systems you did not install?
Yes, most of them. A good share of our work is on systems other people put in, and a fair number of our customers have used us for years without us ever having installed anything for them.
Get on the winterization list
October fills up. Call and we will give you a realistic date rather than a hopeful one.
Call or text
Based in
Lindon, Utah
Serving Utah County & the Wasatch Front
Utah license
10726295-5501
Rated
4.8 from 45 Google reviews
Parade of Homes People’s Choice winner